II 五 、 技 術 參 數 Page31
重量 | 500克 |
尺寸 | L 190mm, W 88mm, H 40 mm |
電源 | 1節9V層疊堿性電池 |
質量認證 | European CE, US FCC 15 |
質量保證期 | 主機一年 |
六、保修
德國柯雷技術有限公司保證它制造的每一個儀表在材料和工藝上沒有缺陷。
所有產品在運送給原始消費者后保修一年。
德國柯雷技術有限公司保留在任何時間改變設計的權利。
此中文使用手冊由德國柯雷技術有限公司翻譯并提供。
II 七 、 附 錄
七、附錄
單位轉換公式
UNITS OF RADIATION MEASUREMENT
The curie is the number of particles per second from 1 gram of Radium = 3.7 x 10 E10 counts/second = 37 billion cps = 37 billion Becquerel.
1 Becquerel (Bq) = 1 count per second = 1 event per second
1 microcurie = 1 uCi = 37,000 Bq = 37,000 cps.
1 microcurie = 2.22 x 10E6 disintegrations / minute = 2,220,000 cpm.
1 nanocurie = 1 billionth of a curie = 2,220 disintegrations / minute.
1 picocurie = 2.2 disintegrations / min.
Dosage units:
Gray (Gy) = 1 Joule/kg
Sievert (Sv) = Gray x QF, where QF is a "quality factor" based on the type
of particle. The Sievert is a measure of biological effect.
QF for electrons, positrons, and xrays = 1 QF = 3 to 10 for neutrons,
protons dependent upon the energy transferred by these heavier particles.
QF = 20 for alpha particles and fission fragments.
Converting older units:
1 rad = 1 centigray = 10 milligrays ( 1 rad = 1cGy = 10 mGy )
1 rem = 1 centisievert = 10 millisieverts ( 1 rem = 1cSv = 10 mSv )
1 mrad = 10 μGy
Nominal background radiation absorbed dose of 100 mrad/year = 1 mGy/yr.
Nominal background radiation dose biological equivalent of 1mrem/year = 10μSv/yr.
Occupational whole body limit is 5 rem/yr = 50 μsv/yr. ( Recently proposed that levels be reduced to 2 rem/yr.)
2.5 mrem/hr or 25 μSv/hr is maximum average working level in industry.
Exposure rate from Naturally Occurring Radioactive Material (NORM) ; an
empirically derived conversion factor for Ra-226 decay series: 1.82 microR/hour = 1 picoCurie/gram.
mR/h=10μSv/h
mR=10μSv