Bligh & Dyer extraction
1) Pellet approximately 1 X 107 cells.
2) Resuspend pellet in 3 ml CHCl3: CH3OH (1:2) and vortex hard.
3) Add 0.8 ml H2O, vortex hard and allow solution to sit at room temperature for atleast 30 minutes.
4) Pellet cellular debris by spinning at 3,000 rpm (in the tabletop centrifuge) for 5 minutes.
5) Transfer solvents to a new tube without transferring any of the pelleted debris.
6) Add 1 ml of CHCl3 and 1 ml of H2O to each sample.
--> Upon addition of CHCl3, a biphasic solution should result.
7) Vortex hard and spin samples at 3,000 rpm (in the tabletop centrifuge) for 5 minutes.
8) Remove the upper aqueous/methanolic phase and transfer the lower CHCl3 phase to a new tube.
--> The CHCl3 phase should constitute 2 ml total volume.
9) Dry down solvent under extra dry nitrogen gas.
10) Resuspend lipids in 1 ml of CHCl3, aliquot 800 μl of lipid suspension for base hydrolysis and 100 μl for phosphate measurement.
Base hydrolysis
9) Bring lipids up to 1 ml volume in CHCl3.
10) Add 100 μl of 2N methanolic NaOH to each sample.
--> The final concentration of base is 0.2N.
11) Incubate samples at 37°C for 1 hour.
12) Neutralize base by adding 100 μl of 2N HCl to each sample.
13) Add 2 ml CH3OH and 600 μl of water to each sample, vortex hard.
14) Allow samples to sit at room temperature for atleast 30 minutes.
15) Add 1 ml CHCl3 to break phases and vortex hard.
16) Complete the extraction by addition of 1 ml of water, vortex hard.
17) Spin samples at 3,000 rpm (in the tabletop centrifuge) for 5 minutes.
18) Aspirate off the upper H2O/methanolic phase and collect the lower, CHCl3 phase.
19) Dry the lipids down under extra dry nitrogen gas, resuspend them in 75μl of CHCl3 , aliquot 10 μl for phosphate measurements and spot 50μl on a TLC plate.
20) Spot standards (1-100 nmoles SM) and develop plates in CHCl3:CH3OH:Acetic acid:H2O (50:30:8:5).
21) Visualize lipids using iodine vapor, mark, and scrape the SM spots into a 13x100 screw-capped tube.
22) Extract the SM from the silica as follows:
a) wash with CHCl3:CH3OH (2:1) 2 times
b) wash with CHCl3:CH3OH (1:2) one time.
23) Quantitate the extracted SM via a standard phosphate assay.
在2024ASMS(美國質譜學會年會)上,全球生命科學分析技術創新者SCIEX與MassAnalytica合作,展示了人工智能定量(AIquant)軟件。AIquant利用人工智能和機器學習的能力,在......
分析測試百科網訊近日,AgenaBioscience宣布在PLOSONE發表了一項比較研究,強調使用其基于質譜平臺和新的高度靈敏的iPLEX?HS化學物質檢測發生在非小細胞肺癌(NSCLC)EGFR、......
高通量、高精確度的RapidFire?Mass方案適用于藥物發現【導語】5月23日至5月27日的ASMS會議上,技術先進,品質優越的ADME分析儀體外整體操作系統在ASMS會議上亮相。2010年5月2......
費城(2009年6月1日)--服務科學,世界領先的賽默飛世爾科技今日宣布推出MassFrontier?6.0–這一功能強大的新型軟件包將為質譜譜圖的管理、評估和解析提供精密的特性。它可廣泛應用于小分子......
......
MassSpectrometry:Instrumentation,Interpretation,andApplications(Wiley-InterscienceSeriesonMassSpectr......
這是比較全的一個綜述,主要列舉了各種東西,所以,不會很深入,但可以留在手邊查查名詞兒。一、進樣系統二、離子源三、質量分析器四、串聯質譜及聯用技術五、數據處理和應用解壓縮后可看到word格式。......
?分辨率是指分開兩個峰的能力,剛剛分開時兩峰之間的質量距離是DM,分辨率英文的原義是Resolution,常用簡寫R表示,計算公式:R=M/DM,M可理解為為兩個剛剛分開的峰的平均質量。?最嚴格的定義......