by Mazen Ferzly, 06/22/2000
The purification of ICAM-1 on R6.5 anti-ICAM-1 column.
Triethylamine
NaCl
Octyl Glucoside ( n-octyl-b-D-glucopyranoside Sigma Cat. No. O-8001)
Tris-Base
NaN3
Tris-HCl
PMSF (PhenylMethylSulfonylFluoride)
Aprotinin
Triton-X 100
100% EtOH
Human IgG Column
R6.5 mAb Column
5ml Falcon 2054 tubes
Adjust pH to 11.0 with concentrated HCl. Be careful!!! Adding concentrated acid to strong alkaline may cause a violent reaction. Add dH2O to 500ml final volume.
Triethylamine 3.5ml (Pipette in fume hood using glass pipette)
NaCl 4.4g
H2O 450ml
Note: Since octyl Glucoside is very expensive, take 100ml of this buffer and add to it 1g of Octyl Glucoside. This will be more than sufficient for one run
Adjust pH to 7.5 with HCl. Add dH2O to 500ml final volume. Add 0.03% NaN3.
Tris-Base 0.76g
NaCl 4.4g
dH2O 450ml
Adjust pH to 8.0 using HCL. Add water to 500ml final volume.
Tris-HCl 0.26g
Tris-Base 0.41g
NaCl 4.4g
dH2O 450ml
Add 1g Octyl Glucoside to 100ml of Wash Buffer.
Add 1ml freshly prepared 100mM PMSF to each 100ml Wash Buffer. Final concentration of 1mM.
Add 1 ml 100X Aprotinin (20 TIU/ml) for each 100ml Wash Buffer. Final concentration of .2 TIU/ml.
Note: PMSF must be prepared fresh each time. Add 0.87g of PMSF to 50ml of 100% EtOH. Be careful !!! PMSF is highly toxic.
Adjust pH to 6.8 with concentrated HCl. Add dH2O to final volume of 100ml.
Tris-Base 12.1g
dH2O 80ml
Adjust pH to 12.0 with concentrated NaOH. Add dH2O to 500ml final volume.
Triethylamine 3.5ml (Pipette in fume hood using glass pipette)
NaCl 4.4g
H2O 450ml
Add 0.5ml Triton-X 100. Mix well.
Pre-wash column with 5 column bed volumes of Pre-wash Buffer to pre-elute any materials that might leach from column. Minimize length of time column is exposed to Pre-wash Buffer because of the harsh denaturing conditions at pH 11.0.
Equilibrate the columns with 5 column bed volumes of Equilibration Buffer to return the column to pH that supernatant will be loaded at.
Assemble the column as by attaching Human IgG column to R6.5 column.
Load supernatant overnight at flow rate not higher than 1ml/minute. The flow rate can be slower, and is desirable for maximum binding.
Note: It is a good idea to include a "safety loop" to prevent a the column from drying out it runs out of liquid.
Separate the two columns.
Wash R6.5 column with at least 10 column bed volumes of Wash Buffer. At same time strip the Human IgG column with 5 column bed volumes of Stripping Buffer.
Equilibrate Human IgG column with 10 column bed volumes of Equilibration Buffer and store at 4oC.
Before beginning elution step of R6.5 column, set up the collection tubes. Use the 5ml Falcon 2054 tubes. On each tube number and mark off the 3ml mark. Add 0.3 ml of the Elution Neutralization Buffer.
Elute the R6.5 column 50ml of Elution Buffer. Elute 3ml in each prepared collection tube. Mix each tube immediately after elution and cap with parafilm to prevent evaporation during storage.
Strip the column with 5 column bed volumes of Stripping Buffer.
Equilibrate the column with 10 column bed volumes of Equilibration Buffer and store at 4oC
O.D. fractions to determine which one have highest concentration of protein
Run protein gel to check concentration and to make sure you have the protein you want.
蛋白質作為構成人體組織器官的支架和主要物質,在人體生命活動中起著重要作用。蛋白質的相互作用能產生許多效應,如形成特異底物作用通道、生成新的結合位點、失活、作用底物專一性和動力學變化等,細胞的代謝、信號......
2021年9月9日,無錫臻和生物科技有限公司(以下簡稱“臻和科技”)與美國VyantBio公司簽署TissueofOrigin?(以下簡稱“TOO?”)全球權益和ZL轉讓協議,全資收購這款唯一獲FDA......
2021年7月20日,JournalofCellularPhysiology及JournalofCellularBiochemistry同時撤回了中國學者49篇文章。從2019年開始,Journalo......
磷酸甘油酸突變酶1(PGAM1)通過其代謝活性以及與其他蛋白質(例如α平滑肌肌動蛋白(ACTA2))的相互作用,在癌癥代謝和腫瘤進展中起關鍵作用。變構調節被認為是發現針對PGAM1的高選擇性和有效抑制......
分析測試百科網訊近日,島津公司推出了NexeraPrep系列制備型純化液相色譜儀(LC)。“制備工作”是從樣品中分離和純化特定物質的過程。該過程對于在制藥工業中的藥物發現期間提取目標化合物和雜質以及提......
2018年12月6日,來自圣迭戈的消息——Illumina公司(納斯達克股票代碼:ILMN)今天宣布推出新型高密度基因分型芯片Infinium?GlobalDiversityArray。這款芯片設計源......
SDS-PAGE異常電泳現象及分析SDS-PAGEHallofShame.pdf 很不錯的東東~~推薦下~......
Preparationofdenaturing6%polyacrylamidegelsformicrosatelliteanalysis(alsoforSSAP,high-resolutionIRAP......